Support > Downloads

VU-DAMS Changelog           

  • 4.9 (pre-release; October 2021)
    • rearrange gui
    • make scl peak detector and thus opening 5fs files faster
    • calculate imp and ecg averages when creating label
    • default values Y-axes
    • QRSTtab: zoom levels slide more intuitive
  • 4.8 (September 2021)
    • added P, P onset points in impedance tab
    • ICG X point after T
    • X axis in milliseconds
    • graph PEP and LVET areas in impedance tab
    • keep order of ECG and ICG points when dragging
    • change order in impedance InfoPanel
  • 4.7 (May 2021)
    • read binary files for testing of ams hardware 7 
    • fix hang issue in output table 
    • use native FileDialog on Mac 
    • enable Ctrl-click in overlays for Mac
  • 4.5 (March 2021)
    • Made label information tab more user friendly:
      • drag and drop rows in Output Config Editor
      • drag and drop columns in main table
      • right click context menu in table header
      • highlight label in the graphic signal overview on click
      • total recording line at the bottom
      • added several columns
      • show a selection of relevant columns by default
    • Remove spurious peaks in OnlineGraph
    • Show SCL peaks in SCL label tab
    • Average HR and MOT over smaller windows
    • Use the same algoritm for deviant beats in RSA tab as in R-peak tab
  • 4.3 (r1156)
    • Added corrected stroke volume, in keeping with Nederend et al. 2017 (http://dx.doi.org/10.1016/j.ijpsycho.2017.07.015).
    • Removed "Age", "Gender", "Weight" and "Height" from Label Info tab.
    • Added minute volume column in keeping w/ Nederend 2017 (c.f. above).
    • Renamed 'old' minute volume column to "Minute Volume (Kubicek 1966)".
    • R-peak annotation and IBI classification: renamed "suspicious" to diverging in interface ("suspicious" is maintained @code level). "Highly suspicious" (colored red) is denoted "deviant" and "medium suspicious" (yellow) is denoted "worth checking".
  • 4.2 (r1136)
    • Added a button in QRSToolbar for removal of all artefacts and rescan of the ECG.
  • 4.1 (r1135)
    • Adjustments for Mac deployment
    • Re-implementation of x-axis tick marks
    • Improved: Automatic labeling using markers/events in batch mode
    • Other minor improvements/additions
  • 4.0 (r1123)
    • Replaced static red grid by dynamic grey grid
    • Append [Subject ID] to Title bar (can be disabled via Settings > General)
    • Improved: File > Batch export data
    • Improved:Impedance Scoring tab > Stroke Volume > Edit
    • Improved Impedance Scoring tab (left panel is now scrollable)
    • Improved Skin Conductance tab
    • Improved:Detect R-Peaks tab > Actions > Show Ectopic Beats
    • Improved: Data > Clear external signals
    • Improved: Data > Export Signal To ASCII
    • Draw SCL in Label Data tab when no ECG and no DZ
    • Other minor improvements/additions
  • 3.9 (r1067)
    • Enabled silent (un)installs with "/S" switch
    • VU-DAMS.app built for Mac platform
    • Automatic labeling using events/markers updated with a new template
    • Option to go to the specific suspicious beat (goto function) in the QRS Tab
    • Included Min & Max SCL Values to the Output data
    • View the ectopic beats (PVC & PAC) in a separate window in QRS Tab
    • Add VU-DAMS Software version number to the header file
    • SVN Revision number retrieved using xml file
    • Other minor improvements/additions
  • 3.8 (r989)
    • Automatic labeling using markers/events in batch mode
    • Import a maximum of three external signals in VU-DAMS
    • Count of Premature Atrial Contractions (PAC's) per label added to the output.
    • ICG Characteristic points detection improved
    • VU-DAMS is supported on Mac OS X
    • Serial Communication stabilized
    • Other minor improvements/additions
  • 3.6 (r938)
    • Combined Set-up for 64 bit and 32 bit Operating Systems
    • Serial Communication is stabilized
    • Possibility to add Demographic data of the subject and save in the amsdata file.
    • Debug Settings File for technical support is created
    • New check for the corrupted amsdata files
    • The batch process logs are presented to the user
    • Other minor improvements/additions
  • 3.5 (r876)
    • DZDT Signal Quality Improved by Filtering
    • Skin Conductance Analysis Updated
    • Watchdog reset and Buffer Overflow error messages implemented
    • AmsSerail.dll now in VU-DAMS setup
    • Other minor improvements/additions
  • 3.4 (r837)
    • Batch Export of Beat Information to text file
    • Possibility to mark Premature Ventricular Contractions
    • More options on right click over the label
    • Export PVC counts per label
    • Other minor improvements/additions
  • 3.3 (r823)
    • Batch Export of Respiration Data
    • Stroke Volume Calculation problem fixed with old '.ams' format files
    • Z0 is now also displayed in Inspect Data tab for old '.ams' format files
    • Save the user setting files to AppData Directory
    • Sync beats detected with Respiration Data
    • All back to 32 bit version for stable serial communication
    • Other minor improvements/additions
  • 3.2 (r802)
    • Import Labels option customized
    • Open and Analyze Files where one or more channels are not recorded with maximum sampling frequency
    • Operating System Check and use of 32/64 bit java respective to operating system
    • Included Java Version and JVM information in the program
    • Event time and Signal Time are synced when raw signal is exported.
    • Electrode distance and Specific Resistivity of the blood values are editable and can be saved to AMSData File.
    • Other minor improvements/additions
  • 3.1 (r743)
    • Other minor improvements / additions
  • 3.0 (r739)
    • Automatic Scoring for ECG Characteristic Points
    • Skin Conductance Data analyzed & presented in a new tab (under development)
    • Label based export of Skin Conductance Data
    • Option to remove all HIGH & MEDIUM Suspicious Beats in Detect R-Peaks Tab
    • Experimental information added to time based labels
    • Divide a particular label into time labels of chosen interval.
    • Batch Export of Raw Signals with & without label information
    • Batch Analyze & Export Data (ASCII & Excel) for automatic scoring of ECG & ICG Complexes
    • Possible to add labels even if only one channel is recorded
    • Fixed freeze with connection lost problems
    • Automatically establishing connection on connection lost during online mode
    • Instant Heart Rate during online mode
    • Other minor improvements / additions
  • 2.2
    • Added Copy/Paste Labels in Label Data tab
    • Added Batch export data to ASCII
    • Added ICG, ECG and SCL warnings in Configure Device window
    • Added "Never ask me again" option to update available window
    • Fixed freeze when opening file without ICG
    • Other minor improvements / additions
  • 2.1
    • Fixed error when updating to Java 7
    • Enabled VU-DAMS suite and Bluetooth database updates via internet
    • VU-DAMS suite version now always visible in upper left corner
    • Other minor improvements / additions
  • 2.0
    • Many improvements / additions
  • 1.01
    • Initial release